COMDTINST M16600.10 — Coast Guard Regulated Facility Compliance Program

COMDTINST M16600.10 governs Coast Guard facility compliance programs and activities for waterfront facilities handling dangerous cargo.

Search COMDTINST M16600.10

  • Publication number: COMDTINST M16600.10
  • Title: COAST GUARD REGULATED FACILITY COMPLIANCE PROGRAM
  • Date: 3/9/2020
  • Proponent: CG-FAC

View COMDTINST M16600.10 on armypubs.army.mil


The publication addresses waterfront facility safety, permits, inspections, hazardous cargo, firefighting, transfer operations, and discharge response. It requires specified compliance activities, protective equipment, MISLE reviews and closure timelines, and facility controls.

Applies to: Waterfront facilities that handle packaged and bulk solid dangerous cargo are regulated under 33 CFR Part 126.

Topics covered

  • Waterfront facility safety
  • Dangerous cargo permits
  • Facility compliance activities
  • Personal protective equipment
  • MISLE activity closure
  • Firefighting equipment
  • Discharge containment equipment
  • Transfer operations

Questions and answers

What smoking rule applies during facility compliance activities?

Given possible interactions with hazardous or explosive materials, Coast Guard personnel are prohibited from smoking while conducting facility compliance activities. (paragraph 6)

What personal protective equipment must facility compliance teams wear?

When conducting facility compliance activities, basic PPE must include: a hard hat, safety glasses, hearing protection, safety shoes, and leather gloves for abrasion hazards. (paragraph 1)

What must happen before hotwork at a waterfront facility?

Prior approval of the COTP is required for such operations under 33 CFR § 126.30. (paragraph 3)

How quickly must activities without deficiencies be closed in MISLE?

In accordance with Reference (f), activities without deficiencies identified should be entered in MISLE and closed within seven days of completion of a facility compliance activity. (paragraph 5)

How often must units identify open activities and unresolved deficiencies?

Not less than once each quarter, each unit must identify open activities and unresolved deficiencies in MISLE, and, if possible, take proper action to close the activity or resolve the deficiency. (paragraph 6)

Ask Reggie.Bot a question about COMDTINST M16600.10