WR-ALCI21-101 — Work Control Documents And Technical Data

WR-ALCI21-101 governs Work Control Documents and technical data processes for Warner Robins Air Logistics Complex.

Search WR-ALCI21-101

  • Publication number: WR-ALCI21-101
  • Title: WORK CONTROL DOCUMENTS AND TECHNICAL DATA
  • Date: 2024-01-24

View WR-ALCI21-101 on armypubs.army.mil


WR-ALCI21-101 addresses WCD requirements, specification and tolerance changes, data collection, critical task notation, and computer-generated WCDs. It requires approved WCDs, documented maintenance data, timely updates, and accurate electronic records.

Applies to: It applies to all Warner Robins Air Logistics Complex (WR-ALC) groups and the Business Operations Office (WR-ALC/OB).

Topics covered

  • Work Control Documents
  • WCD specifications and tolerances
  • Customer Key Characteristics
  • Critical task notation
  • Computer-generated WCDs
  • Electronic WCD processes

Questions and answers

What is the official record for work performed?

The WCD is the official record for work including control, identification, inspection, and routing of operations. (paragraph 2)

When must a WCD be developed?

A WCD shall be developed for all programmed and temporary workloads. (paragraph 2)

How quickly must WCD specification changes be updated?

The planner will ensure WCD is updated within 3 business days after formal posting of the technical order change. (paragraph 2)

What information must be recorded when a Customer Key Characteristic is measured?

Whenever a CKC is measured, the unique identifier of the measuring device will also be recorded (e.g., torque wrench, Precision Measuring Equipment Laboratory (PMEL) ID # F198637). (paragraph 4)

What must mechanics document when a task cannot be completed?

When a task/operation performed by one or more mechanics cannot be completed, the applicable mechanics will turn WCD over and document all maintenance performed up to that point, stamp, and date the entry. (paragraph 4)