QTP4N1X1X-D4 governs Air Force training procedures for air-conduction hearing tests, tympanometry, and ear mold impressions.
View QTP4N1X1X-D4 on armypubs.army.mil
It contains performance checklists for audiology procedures, including patient preparation, ear examination, testing, results, and ear mold follow-up. Evaluation requires completion of all task parts without assistance and documentation of competency after satisfactory completion.
Applies to: This qualification training package (QTP) was developed to make a training aid available that will assist Otolaryngology Surgical Technicians to develop technical skills essential to performing specialized tasks.
The evaluator will STOP the procedure immediately and correct the trainee if performance may compromise patient safety. (paragraph 2)
The trainee must satisfactorily perform all parts of the task with 100% accuracy, without assistance. (paragraph 3)
If unable to print results, record the ear canal volume, peak amplitude of the tympanogram, and pressure point of peak. (paragraph 5)
If the patient experiences pain or bleeding, evaluation by the credentialed provider is indicated. (paragraph 4)
Provide the test results to the referring physician or audiologist. (paragraph 4)