QTP4B071-19 — Air Force Specialty Code 4B071 Bioenvironmental Engieneering Nuclear Enterprise

QTP4B071-19 governs Air Force qualification training for radiological casualty countermeasures, alarm levels, sampling, and decontamination.

Search QTP4B071-19

  • Publication number: QTP4B071-19
  • Title: Air Force Specialty Code 4B071 Bioenvironmental Engieneering Nuclear Enterprise
  • Date: 2015-03-24

View QTP4B071-19 on armypubs.army.mil


It covers isotope-specific medical countermeasures, electronic personal dosimeter alarm settings, air, water, soil, and vegetation sampling strategies, and decontamination procedures. It requires successful completion of checklist items without trainer assistance for the countermeasure task.

Topics covered

  • Radiological casualty countermeasures
  • Electronic personal dosimeter alarm levels
  • Air sampling strategies
  • Water sampling strategies
  • Soil sampling strategies
  • Vegetation sampling strategies
  • Personnel decontamination
  • Vehicle and aircraft decontamination

Questions and answers

Why must the isotope of concern be determined before recommending medical countermeasures?

Determining the isotope of concern because each type of medical countermeasure is isotope specific. (paragraph 1)

How much radiological contamination may removing clothing and shoes remove?

Removing all clothing and shoes may remove up to 90% of radiological contamination. (paragraph 2)

How can internal contamination of a patient be identified?

The most effective way is to perform nasal swabs and use the ADM-300 to determine if the swab contains any alpha, beta or gamma/x-ray contamination. (paragraph 3)

What should happen if internal contamination has occurred?

If internal contamination has occurred, medical countermeasures should be used. (paragraph 4)

What sampling result generally requires further action?

Generally accepted practice is anything greater than twice background readings require further action. (paragraph 2)

Ask Reggie.Bot a question about QTP4B071-19