QTP4B071-19 governs Air Force qualification training for radiological casualty countermeasures, alarm levels, sampling, and decontamination.
View QTP4B071-19 on armypubs.army.mil
It covers isotope-specific medical countermeasures, electronic personal dosimeter alarm settings, air, water, soil, and vegetation sampling strategies, and decontamination procedures. It requires successful completion of checklist items without trainer assistance for the countermeasure task.
Determining the isotope of concern because each type of medical countermeasure is isotope specific. (paragraph 1)
Removing all clothing and shoes may remove up to 90% of radiological contamination. (paragraph 2)
The most effective way is to perform nasal swabs and use the ADM-300 to determine if the swab contains any alpha, beta or gamma/x-ray contamination. (paragraph 3)
If internal contamination has occurred, medical countermeasures should be used. (paragraph 4)
Generally accepted practice is anything greater than twice background readings require further action. (paragraph 2)