QTP4B051-23 governs Air Force bioenvironmental engineering qualification training for nuclear enterprise tasks and evaluations.
View QTP4B051-23 on armypubs.army.mil
It covers radiological casualty care, radiation measurement, survey-meter operation, exposure-risk assessment, and DOEHRS documentation. It requires trainees to complete task steps, answer review questions, and meet performance-checklist criteria.
Determining the isotope of concern because each type of medical countermeasure is isotope specific. (paragraph 1)
Removing all clothing and shoes may remove up to 90% of radiological contamination. (paragraph 2)
Meter readings must be within the upper and lower values to be considered acceptable. (paragraph 1)
Allow the rate reading to stabilize for 20 seconds. (paragraph 4)
When measuring alpha, beta, or x-ray, select the probe appropriate for the type of radiation being measured and attach it to the meter (when the meter is turned OFF). (paragraph 7)