QTP4B051-15 governs EMF exposure limits, hazard-distance calculations, measurement surveys, instrumentation, and probe burnout.
View QTP4B051-15 on armypubs.army.mil
QTP4B051-15 covers emitter data, field selection, tier environments, MPE calculations, EMF surveys, probe orientation, and measurement recording. It requires calculation of duty factor and PDmax for pulsed emitters and use of applicable OEHMIS, DOEHRS, or an equivalent system.
To determine the necessity for performing a survey of the emitter and to determine the distance to begin the survey if needed. (paragraph 1)
Worst case operating parameters under fixed-beam conditions should be used to define the location of action level MPEs whenever possible. (paragraph 3)
Select the probe that is compatible with the field (E or H) being measured and emitter frequency. (paragraph 4)
(1) Connect and turn instrumentation “on” at least 10 minutes before survey measurements are made. (paragraph 1)