HURLBURTFIELDI91-202 governs safety requirements for demolition training and emergency disposal operations on the Hurlburt Field Explosive Training Range.
View HURLBURTFIELDI91-202 on armypubs.army.mil
It sets explosive and personnel limits, equipment requirements, operating locations, safety precautions, emergency procedures, and event sequences. The publication requires coordination, approvals, safety controls, range security, and proper handling of explosives and residue.
Applies to: This publication applies to all base, tenant, Air National Guard (ANG), and Air Force Reserve (AFR) agencies performing training demolition operations on the Hurlburt Field Explosive Training Range.
The maximum amount of explosives per detonation will not exceed 100 pounds Net Explosive Weight (NEW). (paragraph 2)
A minimum of two explosive demolition qualified personnel are required for any explosive operation. (paragraph 3)
Do not detonate fragment-producing munitions on the range. (paragraph 6)
Do not conduct operations when electrical storms are within 5 nautical miles.
Do not conduct operations if sustained wind speed exceeds 15 miles per hour.