HILLAFBI48-105 — Base Ionizing Radiation Safety Program

HILLAFBI48-105 governs precautionary measures and procedures for RAM and ionizing radiation producing machines at Hill AFB.

Search HILLAFBI48-105

  • Publication number: HILLAFBI48-105
  • Title: BASE IONIZING RADIATION SAFETY PROGRAM
  • Date: 2025-09-04

View HILLAFBI48-105 on armypubs.army.mil


HILLAFBI48-105 covers ALARA, radiation safety roles, RAM shipping and storage, dosimetry, training, event notifications, and records. It requires approvals, monitoring, safety equipment, training, reporting, and radiation record controls.

Applies to: It applies to all Hill Air Force Base (AFB) personnel, contractors, tenant organizations, Geographically Separated Units (GSUs: Little Mountain, Utah Test and Training Range, and Carter Creek), and other operating locations controlled by Hill AFB using RAM or radiation producing machines.

Topics covered

  • ALARA concept
  • RAM shipping and storage
  • Dosimetry program
  • Radiation safety training
  • Radiation event notifications
  • RAM waste disposal

Questions and answers

What is the ALARA requirement for radiation exposure?

The ALARA concept is that the lower the exposure to radiation, the lower the risk of adverse health effects. (paragraph 1)

Can an organization procure RAM without IRSO approval?

No organization will procure RAM or radiation producing devices without prior approval of the IRSO. (paragraph 3)

How far in advance must RAM shipping approval be obtained?

Organizations needing to ship RAM must notify the IRSO and obtain IRSO approval, in writing, at least 14 days prior to shipping. (paragraph 3)

Where should a dosimeter be placed?

Never place the dosimeter inside the pocket or behind cloth, cigarettes, coins, or any obstruction whatsoever. (paragraph 5)

What happens if a dosimeter is damaged or exposed?

If these devices are accidentally damaged or exposed, the wearer must immediately return them to 75 OMRS/SGXB for exchange and subsequent evaluation. (paragraph 5)

Ask Reggie.Bot a question about HILLAFBI48-105