HILLAFBI32-7002 — Air Quality Compliance

HILLAFBI32-7002 governs air quality compliance for air emission equipment and processes at Hill Air Force Base.

Search HILLAFBI32-7002

  • Publication number: HILLAFBI32-7002
  • Title: Air Quality Compliance
  • Date: 2026-03-25

View HILLAFBI32-7002 on armypubs.army.mil


HILLAFBI32-7002 covers planning, permitting, emissions inventories, inspections, corrective action, and management review. It requires compliance with applicable air quality regulations and permits, source oversight, reporting, and certification records.

Applies to: This instruction applies to all Hill AFB personnel responsible for the operation, maintenance, and/or management of industrial processes and equipment generating air emissions to comply with local, state, federal, and United States Air Force (USAF, or AF) policies, rules, and regulations.

Topics covered

  • Air emissions inventories
  • Air quality permitting
  • Air emission source management
  • Environmental inspection process
  • Regulatory deviations
  • Corrective action

Questions and answers

What must 75 CEG/CEIEA Air Quality do for air emission sources?

75 CEG/CEIEA Air Quality will oversee the operation of all air emission sources, mobile, portable and stationary, to ensure compliance with federal, state, and local air quality regulations and permits. (paragraph 2)

How often must stationary air emissions inventories be completed?

Complete stationary AEIs annually to meet federal, state, and local reporting requirements as well as support regulatory thresholds comparison of actual emissions. (paragraph 2)

What must Industrial Organizations do with air emission equipment permits?

Industrial Organizations must operate air emission equipment in full compliance with permit terms and conditions. (paragraph 2)

How quickly must known or suspected air quality violations be reported?

Known or suspected violations of federal, state, and local air quality requirements will be promptly reported NLT one business day after discovery to 75 CEG/CEIEA Air Quality Program Manager. (paragraph 2)

How often must Industrial Organizations inspect active air emission sources?

Each Industrial Organization will inspect each of its active air emission sources IAW the schedule established in APIMS, but at a frequency of no less than monthly. (paragraph 2)