DESR6055.09_DAFMAN91-201_PACAFSUP_KADENAABSUP — Explosives Safety Standards

DESR6055.09_DAFMAN91-201_PACAFSUP_KADENAABSUP governs explosives safety operations and compensatory measures at Kadena Air Base.

Search DESR6055.09_DAFMAN91-201_PACAFSUP_KADENAABSUP

  • Publication number: DESR6055.09_DAFMAN91-201_PACAFSUP_KADENAABSUP
  • Title: EXPLOSIVES SAFETY STANDARDS
  • Date: 2026-05-07

View DESR6055.09_DAFMAN91-201_PACAFSUP_KADENAABSUP on armypubs.army.mil


The publication addresses explosive operations at taxiways, combat aircraft parking areas, holding areas, hardened aircraft shelters, and flightline locations. It requires evacuation, fire symbol posting, route controls, notifications, and compliance with approved explosive safety plans.

Applies to: This publication applies to USAF, USA, USN, USMC, and other organizations handling explosives on Kadena Air Base (AB).

Topics covered

  • Explosive operations
  • Compensatory measures
  • Taxiway Delta operations
  • Taxiway Bravo South operations
  • Combat Aircraft Parking Areas
  • Flightline fire symbols
  • Explosive movement routes

Questions and answers

When are compensatory measures mandatory for HD 1.1 operations?

Unless otherwise specified, these compensatory measures are mandatory and apply to HD 1.1 operations.

What access restriction applies during explosive operations at Taxiway Delta?

Personnel in Bldg 3579 will restrict access to the tower to mission essential personnel only.

What happens if an explosive operation at facility 46803 exceeds 3,000 lbs. of HD 1.1?

In the event an explosive operation at facility 46803 exceeds 3,000 lbs. of HD 1.1, Navy Munitions Command (NMC) will ensure all explosive operations in facility 46805 will cease, and all personnel will evacuate beyond the appropriate intraline distance.

What evacuation requirement applies to Taxiway Bravo South explosive operations?

Unrelated personnel will be removed from the cargo processing pad and directed to remain indoors or evacuate the area until the aircraft has departed.

What fire symbol requirement applies to flightline sited locations?

Flightline sited locations (e.g., hardstands, Taxiway Bravo/Delta, HAS) require fire symbol posting when explosives are introduced to the location.