DAFMAN91-203_ACCSUP governs Air Force occupational safety, fire protection, and occupational health standards and mandatory ACC requirements.
View DAFMAN91-203_ACCSUP on armypubs.army.mil
DAFMAN91-203_ACCSUP contains requirements for wire rope terminations, fall protection, machinery shutdown, hazardous energy control, and equipment restoration. It requires specified procedures for clip placement, fall protection, energy isolation, PPE, testing, and notification.
Applies to: It applies to commanders, functional managers, supervisors, and all other ACC personnel. It applies to ACC gained Air Force Reserve Command and Air National Guard units or members.
All angles shown are measured from the vertical. (paragraph 9)
Fall protection shall be provided whenever employees can fall four (4) feet or more. (paragraph 8)
Verify it is safe to shut down the machinery/equipment. (paragraph 2-4)
Verify the work for which hazardous energy control was applied is complete and it’s safe to reenergize the machinery/equipment. (paragraph 2)