CAFI21-105_INCIRLIKABSUP — Fabrication Program

CAFI21-105_INCIRLIKABSUP governs AGE and Munitions Handling Equipment corrosion control prevention at Incirlik Air Base.

Search CAFI21-105_INCIRLIKABSUP

  • Publication number: CAFI21-105_INCIRLIKABSUP
  • Title: Fabrication Program
  • Date: 2022-05-16

View CAFI21-105_INCIRLIKABSUP on armypubs.army.mil


It establishes responsibilities and procedures for corrosion prevention involving Aerospace Ground Equipment and Munitions Handling Equipment. It requires training, inspections, corrosion treatment, condition scoring, documentation, and equipment marking controls.

Applies to: It applies to all units operating on Incirlik AB flightline and aircraft and equipment maintenance areas.

Topics covered

  • Aerospace Ground Equipment corrosion inspections
  • Munitions Handling Equipment corrosion control
  • Corrosion prevention training
  • Corrosion treatment procedures
  • Equipment condition scoring
  • Equipment markings and stencils

Questions and answers

Are units without assigned aircraft required to have a corrosion control program?

Units that do not have assigned aircraft are not required to have a program but will coordinate with owning units QA to resolve waiver issues.

What training satisfies local corrosion prevention training requirements?

Corrosion and Prevention training located at https://367trss.hill.af.mil or applicable training site will satisfy the local corrosion prevention training requirements.

How often or under what guidance must assigned AGE receive corrosion condition inspections?

All assigned AGE will have a corrosion condition inspection IAW T.O. 35- 1-3, Corrosion Prevention and Control, Cleaning, Painting and Marking of USAF Support Equipment.

Who performs AGE corrosion condition inspections?

The inspection will be performed by a qualified AGE technician with assistance from a qualified Aircraft Structural Maintenance (ASM) technician as needed.

How must AGE corrosion treatment be accomplished?

Corrosion treatment of AGE will be accomplished by local contractor IAW T.O. 35-1-3.