AFH32-1290(I) governs field testing, operation, and maintenance of cathodic protection systems at military installations.
View AFH32-1290(I) on armypubs.army.mil
It covers close interval and corrosion surveys, water tank calibration, rectifier checks, anode bed surveys, leak surveys, troubleshooting, and maintenance. It provides procedures for potential, dielectric, casing, resistivity, pH, interference, and other tests.
Maintaining Cathodic Protection Systems requires periodic (recurring) maintenance to ensure proper operation.
The required surveys and intervals are identified in MIL HDBK 1136, Operation and Maintenance of Cathodic Protection Systems.
The Close Interval Corrosion Survey is conducted to ensure that the entire structure has adequate cathodic protection.
Check serviceability of reference electrode (half-cell), meters, meter leads, wire reels, and other equipment.
Other equipment which may be used includes waveform analyzers with pulse generators (for impressed current systems with one to 11 rectifiers), or high input resistant DC voltmeter (10 megaohms or higher), wire reels, intermediate electrode extension, and copper/copper sulfate electrode.