934AWI48-103 governs the Air Force radio frequency radiation safety program for fixed and mobile radiation emitters.
View 934AWI48-103 on armypubs.army.mil
It identifies emitter locations, assigns supervisor and maintenance responsibilities, and addresses RF Awareness training. It requires specific precautions for aircraft radios, radar, LAIRCM, fuel or liquid oxygen servicing, and suspected overexposure.
Applies to: It applies to all personnel assigned permanently or temporarily to the 934 Airlift Wing (AW).
Warning signs will be used on the flight line when the LAIRCM system is operated by maintenance technicians. (paragraph 3)
Aircraft Tactical Air Navigation (TACAN) system: Keep personnel a minimum of 30 inches from antennas when transmitting. (paragraph 3)
Aircraft Radar Warning System: Keep personnel a minimum of 6 feet from front (radiating side) of PLM-4 test simulator during receiver testing. (paragraph 3)
HF, LAIRCM, and Radar shall not be operated. (paragraph 3)
Aircraft liquid oxygen servicing Technical Order (TO) 1C-130H-2-12JG-10-2, 12-14-01 prohibits any radio, radar, or LAIRCM system operation. (paragraph 3)