STP 9-94K13-SM-TG — Soldier`s Manual And Trainer`s Guide, Mos 94k, Apache Attack Helicopter Systems Repairer, Skill Levels 1, 2, And 3

STP 9-94K13-SM-TG governs standardized training tasks for MOS 94K Apache attack helicopter systems repairers at skill levels 1, 2, and 3.

Search STP 9-94K13-SM-TG

  • Publication number: STP 9-94K13-SM-TG
  • Title: SOLDIER`S MANUAL AND TRAINER`S GUIDE, MOS 94K, APACHE ATTACK HELICOPTER SYSTEMS REPAIRER, SKILL LEVELS 1, 2, AND 3
  • Date: 12/07/2007
  • Proponent: T2COM
  • Status: ACTIVE

View STP 9-94K13-SM-TG on armypubs.army.mil


The publication covers EETF operation and maintenance, manual repair, LRU and flight hardware testing, maintenance operations, and maintenance management. Its task standards require performance in accordance with specified technical manuals, completion of maintenance and testing procedures, and observance of safety precautions.

Applies to: All tasks in this publication are trained to peacetime/wartime conditions and apply to the Active Army, the Army National Guard (ARNG)/Army National Guard of the United States (ARNGUS), and the United States Army Reserve (USAR) unless otherwise stated.

Topics covered

  • EETF operation and maintenance
  • EETF manual repair
  • LRU and flight hardware testing
  • Maintenance operations
  • Maintenance management
  • Generator operation
  • Test system self-test
  • Prescribed load list repair parts

Questions and answers

How long can the generator be cranked at one time?

CAUTION: Do not crank more than 15 seconds at a time. (paragraph 3)

How long must the engine-generator set warm up without a load?

CAUTION: To prevent engine carbon deposits, do not run engine-generator sets for more than five minutes at governed speed without load. (paragraph 3)

How long must operators wait before warm-up after turning on the AC and DC standards?

You must wait at least two hours after turning on AC and DC standards before you go ahead with warm-up. (paragraph 2)

What does the test system self-test require?

Standards: A complete self-test of the Peculiar/Electro-Optical Bench is performed in accordance with TM 11-6625-3085-12-1 and TM 11-6625-3081-23-1. (paragraph 7)

What standard applies to UUT testing?

Standards: The UUT is tested in accordance with TPS and TM instructions. (paragraph 4)

Ask Reggie.Bot a question about STP 9-94K13-SM-TG